Hybrid office guide for project teams

Hybrid Office Acoustics: How to Specify Pods and Glass Partitions

How each option is measured, what tested data looks like, and what to check before you put either one in a specification.

Explore Workspace
Where a tested pod sits on the ISO 23351-1 scale
Speech level reduction, D(S,A), in dB. ZUM-S result: 29.5 dB.
ZUM-S 29.5 dB
D
C
B
A
A+
15 20 25 30 33 40 dB

In a hybrid office, people come in to collaborate, run workshops and join video calls with colleagues and clients who are somewhere else. Concentration work, spontaneous calls and confidential conversations now share the same open floor, and noise quickly becomes the main complaint.

For fit-out contractors, interior designers and procurement teams, the practical question is how to provide private space for calls and small meetings: with freestanding acoustic pods, with glass partition walls, or with a combination of both.

This guide goes beyond a general comparison (for that, see our earlier article on office pods vs acoustic partitions). It shows how each option is measured, what tested data looks like, and what to check before you specify either one.

Quick comparison

Acoustic pods Glass partitions
Best for Phone calls, video calls, focus work, small meetings Enclosed meeting rooms, boardrooms, department or executive spaces
Acoustic metric Speech level reduction, D(S,A), ISO 23351‑1 Sound reduction rating of the complete wall (STC or Rw)
Test result ZUM‑S: 29.5 dB, Class B (SGS‑issued report, 2024‑09‑24) Request STC or Rw data for the complete assembly, including the door
Installation About 1 hour per pod Prefabricated aluminium or steel profiles assembled on site; drawings and instructions supplied
Range Office pods from single‑person booths to team meeting pods L‑27, L‑65 and L‑100 systems, single or double glazing depending on the series
On‑site disruption No wet trades or major construction Low to moderate; ceiling and floor junctions need coordination
Relocation Can move with the occupier Demountable systems can be reconfigured; glass may need re‑sizing
Approvals Confirm fire detection, sprinkler and egress requirements early Confirm the same, plus ceiling junction details
Traditional drywall rooms are left out of this comparison on purpose. They are fixed construction with a longer programme and lease-end obligations, which makes them a different category from the two options above.

1. Speech privacy: how the two are measured

Pods and walls are tested differently, so their numbers cannot be compared directly.
Enclosures such as pods

Measured by speech level reduction, D(S,A), under ISO 23351-1. It describes how much a standardised speech signal is reduced by the enclosure, in A-weighted dB.

Walls and partitions
Usually rated with STC (ASTM) or Rw (ISO), single-number ratings of airborne sound insulation between rooms.
ISO 23351-1 classifies enclosures by their D(S,A) result:
CLASS A+ A B C D
D(S,A) >33 dB >30 dB >25 dB >20 dB >15 dB

Enclosures such as pods

The Explore Workspace ZUM-S acoustic booth (W1080 x D1000 x H2260 mm) was tested in a 200 m³ reverberation room under ISO 23351-1:2020. The result was a speech level reduction of 29.5 dB, which is Class B. The test was carried out at South China University of Technology and the report was issued by SGS (report no. GZIN2311000998CM01-1_EN, 2024-09-24).

The enclosure performs best in the mid and high frequencies, where much of speech intelligibility sits, and less well at 125 and 250 Hz. That is typical of lightweight enclosures: low-frequency noise such as equipment rumble is harder to block.

Two limits are worth stating plainly:

Tested model only
The result applies to the tested model only. Other pod sizes need their own test data before any figure is quoted for them.
Lab is not the office
A laboratory figure is not the same as perceived privacy in an office. Background noise, whether the door is closed, and where the pod is placed all matter.

Explore Workspace office pods combine PET acoustic panels with 11 mm laminated glass, and include built-in ventilation, LED lighting and power outlets.

How glass partitions perform

Partition performance depends on the whole system, not only glass thickness: the glazing build-up (laminated glass, double glazing with a cavity), perimeter and door seals, the door itself, and how the wall meets the ceiling and floor. A wall can be rated well on paper and still leak through the door gap or the ceiling void.

L-65 glass partition system

L-100 glass partition system

The Explore Workspace glass partition range covers the L-27 (single glazing, 27 mm profile), L-65 and L-100 (single or double glazing) series, with 10–12 mm glass in aluminium alloy or steel profiles. Because acoustic results depend on glazing, seals, door and ceiling junction, ask for the data that matches the exact configuration you plan to specify.

Takeaway: for individual calls and small meetings, a pod gives speech privacy measured to a recognised standard. For larger enclosed rooms such as boardrooms and training rooms, glass partitions provide the room volume and architectural presence. Compare each option using data that matches its own metric.

2. Flexibility, relocation and lease considerations

Hybrid offices keep changing: headcount, attendance patterns, layouts and sometimes premises.

3. Installation, disruption and approvals

Explore Workspace pods are designed to install in about one hour, so in an occupied office a pod can be placed without clearing an area for days.

Glass partitions follow a longer programme because profiles and glass are made to measure. Our standard lead times are about three weeks for profiles in regular colours (four weeks for custom colours) and two weeks for glass panels once measurements are confirmed, plus about four weeks in transit. Installation drawings and instructions are supplied, and lighting, sprinklers and detection near the wall line should be coordinated with the contractor.

Do not assume either option is exempt from approval. Enclosed spaces inside a larger floor can affect fire detection, sprinkler coverage, emergency lighting and escape routes, and the rules vary by country and building. Raise this with the building owner or fire consultant before ordering.

4. Cost factors to compare

Instead of a headline price comparison, compare what the budget has to cover:

How a pod or partition is treated in accounts (furniture or building improvement) depends on its classification and the country, so confirm with an accountant rather than assume. For a wider view of fit-out budgeting, see our office renovation cost guide.

Sourcing from the manufacturer can simplify specification, customisation and delivery planning. Explore Workspace offers a one-stop service that runs from space planning and 3D design to manufacturing, delivery and support.

5. Combining pods and partitions: a zoned approach
Most hybrid offices work best with both, each placed where it fits.

Boardrooms and executive rooms

Formal meetings, presentations, larger groups

Glass partitions with acoustic-rated doors and seals

Open collaboration

Team work, ambient chatter

Acoustic wall and ceiling products, desk screens, baffles

On-demand calls and focus

Quick private calls, video meetings, solo focus

Single-person pods and small meeting pods near workstation clusters

Breakout and lounge

Informal discussion

Soft seating, acoustic wall panels, mobile dividers

Place pods close to workstation clusters so people can step into a private call without booking a meeting room.

Use a glass-partitioned room with an acoustic-rated door and display equipment, furnished from our meeting furniture range.

Absorptive panels, desk screens and baffles reduce reverberation and chatter. They improve the general environment but do not create private rooms.

There is no universal ratio. Start from peak attendance, the share of the day spent on video calls and how many people share each area, then add units if booking data shows queues.

6. Buying checklist for project teams

Acoustic pods

☑ ISO 23351-1 result: ask for the D(S,A) value and class, and confirm which model and size was tested.
☑ Test conditions: whether the door was closed and ventilation running during the test.
☑ Ventilation: airflow and fan noise in operation.
☑ Glazing: glass type, thickness and safety certification.
☑ Interior materials: fire performance certificates for the specific lining material, and emissions information if indoor air quality matters.
☑ Power, data and lighting: sockets, USB charging, lighting controls and regional plug standards.
☑ Handling: dimensions against lifts and doorways, and how the unit ships and installs.
☑ Installation: time required and number of installers.

Glass partitions

☑ Acoustic data for the complete assembly including the door, not only the glass.
☑ Seals: door perimeter and floor seals, and how the wall meets the ceiling.
☑ Glass: build-up, safety rating, and whether acoustic laminated glass is available.
☑ Frame: material, finish options and tolerances.
☑ Doors and hardware: pivot, sliding or hinged options and the acoustic rating of each.
☑ Reconfiguration: what can be reused if the layout changes.
☑ Building requirements: any fire or building details the project needs.

Frequently asked questions

No enclosure is completely soundproof. Pods are designed for speech privacy. In laboratory testing under ISO 23351-1, the ZUM-S achieved a speech level reduction of 29.5 dB (Class B). How private a call feels in practice also depends on background noise, whether the door is closed and where the pod is placed.

Explore Workspace pods include built-in ventilation fans and LED lighting. Always confirm with the building owner how the pod interacts with fire detection and sprinklers.

Demountable systems are designed to be taken down and reinstalled, and the aluminium or steel profiles and hardware can usually be reused. Glass panels may need re-sizing for a different ceiling height or layout.

There is no universal ratio. Start from peak attendance, call frequency and how many people share each area, then adjust using booking data.

It depends on the product, customisation, quantity and destination. For glass partitions, our standard schedule is about three weeks for profiles in regular colours (four for custom colours) and two weeks for glass panels once measurements are confirmed, plus about four weeks in transit. Contact us with your project details for pod schedules.

Conclusion
A hybrid office works when it supports different modes of work. Pods give people private space for calls and focus, partitions give larger rooms with architectural presence, and acoustic treatment in the open areas keeps the overall noise level down. Choose each by the job it has to do, and ask suppliers for test data that matches the metric.

Planning a hybrid office project?

Send us your floor plan, target headcount and project requirements through the contact page. Explore Workspace supports projects from space planning and 3D design through manufacturing, delivery and after-sales support, and showroom visits are available by appointment.